Besa HL7 2.x Help FileGetting Started Units Class Hierarchy Classes, Interfaces, Objects and Records Types Variables Constants Functions and Procedures Identifiers |
Class TbsOMI_O23_ORDER_26
Unit
BSHL7Grp26
Declaration
type TbsOMI_O23_ORDER_26 = class(TBSHL7Object)
Description
Represents the ORDER Group. A Group is an ordered collection of message segments that can repeat together or be optionally in/excluded together. This Group contains the following elements:
ORC, required
TIMING, optional repeating
OBR, required
NTE, optional repeating
ROL, optional repeating
CTD, optional
DG1, optional repeating
OBSERVATION, optional repeating
IPC, required repeating
Hierarchy
Overview
Methods
Properties
Description
Methods
|
function TIMINGRepCount : Integer; |
|
|
function NTERepCount : Integer; |
|
|
function ROLRepCount : Integer; |
|
|
function DG1RepCount : Integer; |
|
|
function OBSERVATIONRepCount : Integer; |
|
|
function IPCRepCount : Integer; |
|
Properties
|
property ORC : TbsORC_26 read GetORC write SetORC ; |
ORC, Usage : R, Min : 1, Max : 1
|
|
property OBR : TbsOBR_26 read GetOBR write SetOBR ; |
OBR, Usage : R, Min : 1, Max : 1
|
|
property NTE[RepCount:Integer]: TbsNTE_26 read GetNTE; |
NTE, Usage : O, Min : 0, Max : *
|
|
property ROL[RepCount:Integer]: TbsROL_26 read GetROL; |
ROL, Usage : O, Min : 0, Max : *
|
|
property CTD : TbsCTD_26 read GetCTD write SetCTD ; |
CTD, Usage : O, Min : 0, Max : 1
|
|
property DG1[RepCount:Integer]: TbsDG1_26 read GetDG1; |
DG1, Usage : O, Min : 0, Max : *
|
|
property IPC[RepCount:Integer]: TbsIPC_26 read GetIPC; |
IPC, Usage : R, Min : 1, Max : *
|
Generated by PasDoc 0.14.0.
|