type TbsTCC_271 = class(TbsHL7Segment)
Description
Test Code Configuration The test (e.g., analyte) code configuration segment is the data necessary to maintain and transmit information concerning the test entity codes that are being used throughout the "automated system."
Hierarchy
Overview
Properties
Description
Properties
|
property UniversalServiceIdentifier : TbsCWE_271 read GetUniversalServiceIdentifier write SetUniversalServiceIdentifier; |
Universal Service Identifier, Min : 1, Max : 1
|
|
property EquipmentTestApplicationIdentifier : TbsEI_271 read GetEquipmentTestApplicationIdentifier write SetEquipmentTestApplicationIdentifier; |
Equipment Test Application Identifier, Min : 1, Max : 1
|
|
property SpecimenSource : TbsST_271 read GetSpecimenSource write SetSpecimenSource; |
Specimen Source, Min : 0, Max : 1
|
|
property AutodilutionFactorDefault : TbsSN_271 read GetAutodilutionFactorDefault write SetAutodilutionFactorDefault; |
Auto-dilution Factor Default, Min : 0, Max : 1
|
|
property RerunDilutionFactorDefault : TbsSN_271 read GetRerunDilutionFactorDefault write SetRerunDilutionFactorDefault; |
Rerun Dilution Factor Default, Min : 0, Max : 1
|
|
property PredilutionFactorDefault : TbsSN_271 read GetPredilutionFactorDefault write SetPredilutionFactorDefault; |
Pre-dilution Factor Default, Min : 0, Max : 1
|
|
property EndogenousContentOfPredilutionDiluent : TbsSN_271 read GetEndogenousContentOfPredilutionDiluent write SetEndogenousContentOfPredilutionDiluent; |
Endogenous Content Of Pre-dilution Diluent, Min : 0, Max : 1
|
|
property InventoryLimitsWarningLevel : TbsNM_271 read GetInventoryLimitsWarningLevel write SetInventoryLimitsWarningLevel; |
Inventory Limits Warning Level, Min : 0, Max : 1
|
|
property AutomaticRerunAllowed : TbsID_271 read GetAutomaticRerunAllowed write SetAutomaticRerunAllowed; |
Automatic Rerun Allowed, Min : 0, Max : 1
|
|
property AutomaticRepeatAllowed : TbsID_271 read GetAutomaticRepeatAllowed write SetAutomaticRepeatAllowed; |
Automatic Repeat Allowed, Min : 0, Max : 1
|
|
property AutomaticReflexAllowed : TbsID_271 read GetAutomaticReflexAllowed write SetAutomaticReflexAllowed; |
Automatic Reflex Allowed, Min : 0, Max : 1
|
|
property EquipmentDynamicRange : TbsSN_271 read GetEquipmentDynamicRange write SetEquipmentDynamicRange; |
Equipment Dynamic Range, Min : 0, Max : 1
|
|
property Units : TbsCWE_271 read GetUnits write SetUnits; |
Units, Min : 0, Max : 1
|
|
property ProcessingType : TbsCWE_271 read GetProcessingType write SetProcessingType; |
Processing Type, Min : 0, Max : 1
|