Besa HL7 2.x Help FileGetting Started Units Class Hierarchy Classes, Interfaces, Objects and Records Types Variables Constants Functions and Procedures Identifiers |
Class TbsOM2_22
Unit
BSHL7DT22
Declaration
type TbsOM2_22 = class(TbsHL7Segment)
Description
Numeric Observation This segment contains attributes of observations with continuous values (including those with data types of numeric, date, or time stamp). It can be applied to observation batteries of type A and C (see OM1-19nature of test/observation).
Hierarchy
Overview
Methods
Properties
Description
Methods
|
function RangeOfDecimalPrecisionRepCount : Integer; |
|
|
function DeltaCheckCriteriaRepCount : Integer; |
|
Properties
|
property SegmentTypeId : TbsST_22 read GetSegmentTypeId write SetSegmentTypeId; |
Segment Type Id, Min : 1, Max : 1
|
|
property SequenceNumberTestObservationMasterFile : TbsNM_22 read GetSequenceNumberTestObservationMasterFile write SetSequenceNumberTestObservationMasterFile; |
Sequence Number - Test/ Observation Master File, Min : 0, Max : 1
|
|
property UnitsOfMeasure : TbsCE_22 read GetUnitsOfMeasure write SetUnitsOfMeasure; |
Units Of Measure, Min : 0, Max : 1
|
|
property RangeOfDecimalPrecision[RepCount:Integer]: TbsNM_22 read GetRangeOfDecimalPrecision write SetRangeOfDecimalPrecision; |
Range Of Decimal Precision, Min : 0, Max : *
|
|
property CorrespondingSiUnitsOfMeasure : TbsCE_22 read GetCorrespondingSiUnitsOfMeasure write SetCorrespondingSiUnitsOfMeasure; |
Corresponding Si Units Of Measure, Min : 0, Max : 1
|
|
property SiConversionFactor : TbsTX_22 read GetSiConversionFactor write SetSiConversionFactor; |
Si Conversion Factor, Min : 0, Max : 1
|
|
property ReferencenormalRangeOrdinalContinuousObservations : TbsCM_RFR_22 read GetReferencenormalRangeOrdinalContinuousObservations write SetReferencenormalRangeOrdinalContinuousObservations; |
Reference (normal) Range - Ordinal & Continuous Observations, Min : 0, Max : 1
|
|
property CriticalRangeForOrdinalAndContinuousObservations : TbsCM_RANGE_22 read GetCriticalRangeForOrdinalAndContinuousObservations write SetCriticalRangeForOrdinalAndContinuousObservations; |
Critical Range For Ordinal And Continuous Observations, Min : 0, Max : 1
|
|
property AbsoluteRangeForOrdinalAndContinuousObservations : TbsCM_ABS_RANGE_22 read GetAbsoluteRangeForOrdinalAndContinuousObservations write SetAbsoluteRangeForOrdinalAndContinuousObservations; |
Absolute Range For Ordinal And Continuous Observations, Min : 0, Max : 1
|
|
property DeltaCheckCriteria[RepCount:Integer]: TbsCM_DLT_22 read GetDeltaCheckCriteria write SetDeltaCheckCriteria; |
Delta Check Criteria, Min : 0, Max : *
|
|
property MinimumMeaningfulIncrements : TbsNM_22 read GetMinimumMeaningfulIncrements write SetMinimumMeaningfulIncrements; |
Minimum Meaningful Increments, Min : 0, Max : 1
|
Generated by PasDoc 0.14.0.
|