Besa HL7 2.x Help FileGetting Started Units Class Hierarchy Classes, Interfaces, Objects and Records Types Variables Constants Functions and Procedures Identifiers |
Class TbsADT_A38_271
Unit
BSHL7271
Declaration
type TbsADT_A38_271 = class(TbsHL7Message)
Description
Represents a ADT_A38(Cancel pre-admit) message structure. This structure contains the following elements:
MSH, required
SFT, optional repeating
UAC, optional
EVN, required
PID, required
PD1, optional
PV1, required
PV2, optional
DB1, optional repeating
OBX, optional repeating
DG1, optional repeating
DRG, optional
Hierarchy
Overview
Methods
Properties
Description
Methods
|
function SFTRepCount : Integer ; |
|
|
function DB1RepCount : Integer ; |
|
|
function OBXRepCount : Integer ; |
|
|
function DG1RepCount : Integer ; |
|
|
procedure Init; override; |
|
Properties
|
property MSH : TbsMSH_271 read GetMSH write SetMSH; |
MSH, Min : 1, Max : 1
|
|
property SFT[RepCount:Integer]: TbsSFT_271 read GetSFT write SetSFT; |
SFT, Usage : O, Min : 0, Max : *
|
|
property UAC : TbsUAC_271 read GetUAC write SetUAC; |
UAC, Min : 0, Max : 1
|
|
property EVN : TbsEVN_271 read GetEVN write SetEVN; |
EVN, Min : 1, Max : 1
|
|
property PID : TbsPID_271 read GetPID write SetPID; |
PID, Min : 1, Max : 1
|
|
property PD1 : TbsPD1_271 read GetPD1 write SetPD1; |
PD1, Min : 0, Max : 1
|
|
property PV1 : TbsPV1_271 read GetPV1 write SetPV1; |
PV1, Min : 1, Max : 1
|
|
property PV2 : TbsPV2_271 read GetPV2 write SetPV2; |
PV2, Min : 0, Max : 1
|
|
property DB1[RepCount:Integer]: TbsDB1_271 read GetDB1 write SetDB1; |
DB1, Usage : O, Min : 0, Max : *
|
|
property OBX[RepCount:Integer]: TbsOBX_271 read GetOBX write SetOBX; |
OBX, Usage : O, Min : 0, Max : *
|
|
property DG1[RepCount:Integer]: TbsDG1_271 read GetDG1 write SetDG1; |
DG1, Usage : O, Min : 0, Max : *
|
|
property DRG : TbsDRG_271 read GetDRG write SetDRG; |
DRG, Min : 0, Max : 1
|
Generated by PasDoc 0.14.0.
|